WHAT IS TITRATION AND TYPES OF TITRATION




A titration (titrimetry) is a technique where a solution of known concentration is used to determine the concentration of an unknown solution. Typically, the titrant (the know solution) is added from a buret  to a known quantity of the analyte (the unknown solution) until the reaction is complete. Knowing the volume of titrant added allows the determination of the concentration of the unknown. Often, an indicator is used to usually signal the end of the reaction, the endpoint.

Titrations can be classified by the type of reaction. Different types of titration reaction include:
  • Acid-base titrations are based on the neutralization reaction between the analyte and an acidic or basic titrant. These most commonly use a pH indicator, a pH meter, or a conductance meter to determine the endpoint.
  • Redox titrations are based on an oxidation-reduction reaction between the analyte and titrant. These most commonly use a potentiometer or a redox indicator to determine the endpoint. Frequently either the reactants or the titrant have a colour intense enough that an additional indicator is not needed.
  • Complexometric titrations are based on the formation of a complex between the analyte and the titrant. The chelating agent EDTA is very commonly used to titrate metal ions in solution. These titrations generally require specialized indicators that form weaker complexes with the analyte. A common example is Eriochrome Black T for the titration of calcium and magnesium ions.
  • A zeta potential titration characterizes heterogeneous systems, such as colloids. Zeta potential plays role of indicator. One of the purposes is determination of iso-electric point when surface charge becomes 0. This can be achieved by changing pH or adding surfactant. Another purpose is determination of the optimum dose of the chemical for flocculation or stabilization

  • ·         Gas phase titration

          Gas phase titrations are titrations done in the gas phase, specifically as methods for determining         reactive species by reaction with an excess of some other gas, acting as the titrant. In one common gas phase titration, gaseous ozone is titrated with nitrogen oxide according to the reaction
O3 + NO → O2 + NO2.
After the reaction is complete, the remaining titrant and product are quantified (e.g., by FTIR);  this is used to determine the amount of analyte in the original sample.
Gas phase titration has several advantages over simple spectrophotometry. First, the measurement does not depend on path length, because the same path length is used for the measurement of both the excess titrant and the product. Second, the measurement does not depend on a linear change in absorbance as a function of analyte concentration as defined by the Beer Lambard Law, Third, it is useful for samples containing species which interfere at wavelengths typically used for the analyte.


Popular posts from this blog

Disintegration Time for tablets as per IP, BP and USP

Disintegration Time:- Uncoated Tablet NMT 15 min, in water with Disc 37 0 C ± 2 0 C Coated Tablet NMT 30 min, In water with Disc for Film Coated Tab , and NMT 60 min Other than Film coated tablet Enteric Coated Tab Intact for 2 hr in 0.1 N HCl & disintegrate within 1 hr in Mixed 6.8 Phosphate buffer. According to USP 2 hr in Simulated gastric fluid, then in Simulated Intestinal Fluid. Dispersible/Soluble Within 3 min in water at 25 0 C ± 1 0 C ( IP ) & 15 – 25 0 C ( BP ) Orodispersible Within 1 min Effervescent Tab 5 min in 250 ml water at 20 – 30 0 C ( IP ) & 5  min in 200 ml water at 15-25 0 C ( BP ) Buccal & Sublingual Not Applicable but dissolve within 15 – 30 min. DT Apparatus:- Mesh Apperture:- 2mm (#10), Cycles:- 28 – 32 cycles/min, 50 – 60 mm distance from bottom & top, Temp of water 37 0 C ± 2 0 C. If 1 or 2 tabs fail, repeat for 12 tabs. Click to Buy Here

Weight variation limit for tablet and capsule.

Weight Variation Limits:- 1) For Tablets  IP/BP.                           Limit.                          USP 80 mg or less.             10%                     130mg or less  80 mg to 250mg.       7.5%               130mg to 324mg 250mg or more.          5%               More than 324mg 2) For Capsule:- IP Limit Less than 300mg 10% 300mg or More 7.5%

Basics and use of HVAC system in pharma

HVAC is an essential aspect in pharmaceutical industry as factors like temperature, relative humidity and ventilation have a direct impact on the quality of the pharmaceutical product. The designing of the HVAC should be sorted out while design concept of facility is in progress as it is linked to the architectural layouts like air locks, doorways and lobbies. Once the HVAC system is properly designed and installed it not only helps to create the required room pressure differential cascades but also prevents the cross contamination. Basically an HVAC system works by transferring the heat and moisture into and out of the air and controls the level of the air pollutant either by removing them or diluting them to a particular level. TECHNOLOGY OVERVIEW: HVAC system varies according to the size and installation capacity within a facility but the basic components remain almost the same. LAYOUT OF A TYPICAL BASIC HVAC SYSTEM HEATING SYSTEM: The heat source is either a furnace or ...