Preparation Process for Water for Injection (WFI) in Pharmaceuticals



There are basically two types of water preparation in pharmaceuticals.Water for Injection (WFI) preparation process and Purified Water preparation process. The analytical standards for the two water are almost very similar, the only difference is that Water for Injection (WFI) system in pharmaceuticals has stricter bacterial control standards than purified water process and has to pass the bacterial endotoxin test. Preparation methods are very similar to a particular point, however, Water for Injection (WFI) preparation process in pharmaceuticals must include distillation or double pass reverse osmosis techniques.

Water for Injection (WFI) preparation process in pharmaceuticals systems, involves several steps and processes this includes; dechlorination, ion reduction, bacterial control, and removal of specific impurities.

Dechlorination:
This refers to the removal of chlorine from the water. There are several ways of dechlorination.This include injection of a reducing agent like sodium metabisulfite and exposure to a high dosage of UV rays can dechlorinate. However, the most common one is filtration through activated carbon media. Water for Injection (WFI) preparation process in pharmaceuticals is dechlorinated by carbon. Carbon dechlorinates by chemically reacting with the free chlorine in water to form hydrochloric acid and carbon monoxide or dioxide. High doses of UV light rays are widely used in water purification systems for both disinfection and TOC reduction. Another use of UV is dechlorination though it is a relatively new process.


Ion removal:
 There are basically three types of ion reduction processes these include membrane processes, ion exchange processes, and distillation processes. Membranes are used in water purification systems to remove ions, remove particulate, remove organic compounds, and remove living organisms. Membranes are different from one another in terms of pore size, molecular weight, and even on ion rejection. Ion removal membranes include membranes such as reverse osmosis membranes and nanofiltration membranes. These are used in ion reduction processes. The ion exchange systems provide additional ion reduction process, making the water much lower in conductivity than required and it also provides a back up for membrane process. Distillation can also be used to remove ion, however, it is very expensive.

Bacterial control:
In bacteria control, one has to be careful to ensure that bacteria does not pass to pharmaceutical water for injection. Bacteria control includes both procedures and equipment. Equipment utilized are ultraviolet (UV) lights, ozone generation systems for production of ozone, heating systems for thermal treatment, and chemical injection and recirculation systems. Procedures in this process include periodic sanitizations and also general operational techniques to avoid intrusion of bacteria. Bacterial control is usually applied during processing, storage and even distribution. UV light is an excellent non-chemical method of disinfecting Water for Injection (WFI). Thermal sanitization involves the use of heat to kill the bacteria. Ozone can also be used since it is a very strong oxidizing agent it can, therefore, oxidize bacteria. Chemicals can also be used to kill bacteria as a means of bacteria control.

Removal of specific impurities:
There are various different sources of water for Injection (WFI) used during preparation process in pharmaceuticals. Every source is different and therefore the possibilities of specific contaminant problem are possible. These contaminants include Iron, manganese, hydrogen sulfide, hardness ions, particulate matter, high conductivity. Filtration can be used to remove any heavy loads. Cartridge filters are also used to remove essentially any sized particles. However, they are expensive.

The last stage is storage. Care and hygiene must be maintained during storage of WFI. Bacteria control must also be incorporated at this stage.

Popular posts from this blog

Disintegration Time for tablets as per IP, BP and USP

Disintegration Time:- Uncoated Tablet NMT 15 min, in water with Disc 37 0 C ± 2 0 C Coated Tablet NMT 30 min, In water with Disc for Film Coated Tab , and NMT 60 min Other than Film coated tablet Enteric Coated Tab Intact for 2 hr in 0.1 N HCl & disintegrate within 1 hr in Mixed 6.8 Phosphate buffer. According to USP 2 hr in Simulated gastric fluid, then in Simulated Intestinal Fluid. Dispersible/Soluble Within 3 min in water at 25 0 C ± 1 0 C ( IP ) & 15 – 25 0 C ( BP ) Orodispersible Within 1 min Effervescent Tab 5 min in 250 ml water at 20 – 30 0 C ( IP ) & 5  min in 200 ml water at 15-25 0 C ( BP ) Buccal & Sublingual Not Applicable but dissolve within 15 – 30 min. DT Apparatus:- Mesh Apperture:- 2mm (#10), Cycles:- 28 – 32 cycles/min, 50 – 60 mm distance from bottom & top, Temp of water 37 0 C ± 2 0 C. If 1 or 2 tabs fail, repeat for 12 tabs. Click to Buy Here

Weight variation limit for tablet and capsule.

Weight Variation Limits:- 1) For Tablets  IP/BP.                           Limit.                          USP 80 mg or less.             10%                     130mg or less  80 mg to 250mg.       7.5%               130mg to 324mg 250mg or more.          5%               More than 324mg 2) For Capsule:- IP Limit Less than 300mg 10% 300mg or More 7.5%

Basics and use of HVAC system in pharma

HVAC is an essential aspect in pharmaceutical industry as factors like temperature, relative humidity and ventilation have a direct impact on the quality of the pharmaceutical product. The designing of the HVAC should be sorted out while design concept of facility is in progress as it is linked to the architectural layouts like air locks, doorways and lobbies. Once the HVAC system is properly designed and installed it not only helps to create the required room pressure differential cascades but also prevents the cross contamination. Basically an HVAC system works by transferring the heat and moisture into and out of the air and controls the level of the air pollutant either by removing them or diluting them to a particular level. TECHNOLOGY OVERVIEW: HVAC system varies according to the size and installation capacity within a facility but the basic components remain almost the same. LAYOUT OF A TYPICAL BASIC HVAC SYSTEM HEATING SYSTEM: The heat source is either a furnace or ...