Skip to main content

SOP OF CORRECTIVE AND PREVENTIVE ACTIONS (CAPA)



1.0 OBJECTIVE:


To lay down the procedure for to be followed for administration of Corrective and Preventive actions (CAPA) including tracking and reporting of the status of CAPA.
2.0 SCOPE:
This SOP shall be applicable for track and follow up open CAPA as well as verification of completed CAPA.
Corrective action:
Action taken to rectify, fix or correct a specific deviation, defect or undesirable situation.
Preventive action:
Action taken to eliminate the cause of deviation, defect, or other undesirable situation in order to prevent the future occurrence of such or similar an event.
Source documents of CAPA are identified as:
  • GMP Investigations
  • Deviations
  • Laboratory (OOS) Investigations
  • Internal Audit Reports
  • External / Customer Audits
  • Annual Product Reviews
  • Regulatory Inspection Reports
  • Management Action Plans
  • Changes in regulatory / Pharmacopoeia requirements 
  • Product Failures
  • Complaints
  • Product recall
  • Returned Goods
  • Incidence Reports
  • Discrepancies
3.0 RESPONSIBILITY:
All Department Heads
4.0 ACCOUNTABILITY:
Head Quality Assurance
5.0 PROCEDURE:
5.1 Source document shall provide the proposed corrective and preventive actions. The proposed corrective and preventive actions shall be approved by QA prior to implementation. The proposed corrective and preventive actions shall be verified during CAPA evaluation in form.
5.2 The "CAPA" form shall be treated as a tracking form of Corrective and Preventive actions from source document.
5.3 Initiation of CAPA:
5.3.1 Department Head shall decide the need for CAPA during initiation of any source document mentioned in Scope.
5.3.2 The Department Head shall get a CAPA form issued from QA. QA shall write the source document name and Source document number on the form before issue of form. Record of CAPA form issued shall be maintained by QA.
5.3.3 Department Head shall fill the CAPA form as under.
5.3.3.1 Write the name of the department
5.3.3.2 Date CAPA initiated
5.3.3.3 Proposed completion date
5.3.4 Carry out root cause analysis and write description based on the source document.
5.3.5 Write in brief the CAPA description from the source document and corrective and preventive action details.
5.3.6 The Department Head shall write their name with signature and date.
5.3.7 The department head shall send the CAPA form to QA.
5.3.8 GM QA / Designee shall allot a reference number to the CAPA form and make relevant entries in the CAPA log. Forward the CAPA form to the concerned department.
5.3.9 The CAPA shall be numbered serially in the calendar year for each department with an identification code of department. A typical CAPA form shall be numbered as
CAPA/XXX/YYY/Z
Where,
XXX: department code.
YYY: serial number, commencing at 001 for each department in calendar year.
Z: Last two digits of a calendar year.
e.g. CAPA/PRD/007/15 represents the 7th CAPA from production department in calendar year 2015

DEPARTMENT CODES

QAD - Quality Assurance Dept.
QCD - Quality Control Dept.
PRD - Production Dept.
WHD - Ware House Dept.
ENG - Engineering Dept. 
HRD - Human Resource Dept. 
PKD - Packaging development Dept.
EHS - Environment Health & Safety Dept.
5.4 CAPA Closure and Verification:
5.4.1 On completion of actions, the department head shall certify that the proposed CAPA is completed and implemented along with associated actions.
5.4.2 QA shall verify the implementation and completion of CAPA with review of supporting documents and certify the same.
5.5 Any change proposed as a result of CAPA shall be through the SOP on Change Control. Reference of the same shall be mentioned in the CAPA format.
5.6 All Deviations, Discrepancy reports giving rise to CAPA shall be addressed through CAPA form.
5.7 All facility up-gradations / Capital purchase requirements / major changes in quality system for compliance to regulatory commitments giving rise to CAPA shall be addressed through CAPA form.
5.8 The record of each CAPA shall be maintained.
Copy of the completed CAPA shall be provided to the concerned Dept. Head by QA. A copy of CAPA form shall be attached to the source document.
5.9 Department Head shall compile the CAPA information and submit the summary to the Management during GMP Committee meeting / Management Review Meeting.
5.10 Management shall review / verify the same quarterly in Management Review Meeting.
5.11 Information and documents related to CAPA drawn form internal audits, external/ Customer audits and regulatory inspections are considered confidential and can only be made available to regulatory review when approved by Director Technical and Sr. Vice President.
6.0 ABBREVIATIONS:
6.1 SOP: Standard Operating Procedure
6.2 CAPA: Corrective Action and Preventive Action
6.3 GMP: Good Manufacturing Practices
6.4 OOS: Out of Specification
6.5 GM: General Manager

                                                     ANNEXURE-1
                                              Request form for CAPA

Originating Department Name

Date

Request No.

Present Process / Problem :


                                                                                                      
Proposed Action (If any ):


Acceptance Criteria of proposed action :


Approval by Head of Originating Department :


                                                                                                               Signature/Date
                                                    

                                                       ANNEXURE-2
                FORMAT FOR CORRECTIVE AND PREVENTIVE ACTION
Department Name :-                                                         Report No.
Ref. request No.(if any):-
Description :


Corrective action:-
Target date of completion
Completion Date





Preventive Action :-


                  
Acceptance Criteria :-


Approval:-



Head Originating department                                                   Head Quality Assurance
(Sign./Date)                                                                                (Sign./Date)
Implementation and Follow up  verified by


Originating department                                                                 Quality Assurance
(Sign./Date)                                                                                    (Sign./Date)

Popular posts from this blog

Disintegration Time for tablets as per IP, BP and USP

Disintegration Time:- Uncoated Tablet NMT 15 min, in water with Disc 37 0 C ± 2 0 C Coated Tablet NMT 30 min, In water with Disc for Film Coated Tab , and NMT 60 min Other than Film coated tablet Enteric Coated Tab Intact for 2 hr in 0.1 N HCl & disintegrate within 1 hr in Mixed 6.8 Phosphate buffer. According to USP 2 hr in Simulated gastric fluid, then in Simulated Intestinal Fluid. Dispersible/Soluble Within 3 min in water at 25 0 C ± 1 0 C ( IP ) & 15 – 25 0 C ( BP ) Orodispersible Within 1 min Effervescent Tab 5 min in 250 ml water at 20 – 30 0 C ( IP ) & 5  min in 200 ml water at 15-25 0 C ( BP ) Buccal & Sublingual Not Applicable but dissolve within 15 – 30 min. DT Apparatus:- Mesh Apperture:- 2mm (#10), Cycles:- 28 – 32 cycles/min, 50 – 60 mm distance from bottom & top, Temp of water 37 0 C ± 2 0 C. If 1 or 2 tabs fail, repeat for 12 tabs. Click to Buy Here

Weight variation limit for tablet and capsule.

Weight Variation Limits:- 1) For Tablets  IP/BP.                           Limit.                          USP 80 mg or less.             10%                     130mg or less  80 mg to 250mg.       7.5%               130mg to 324mg 250mg or more.          5%               More than 324mg 2) For Capsule:- IP Limit Less than 300mg 10% 300mg or More 7.5%

Basics and use of HVAC system in pharma

HVAC is an essential aspect in pharmaceutical industry as factors like temperature, relative humidity and ventilation have a direct impact on the quality of the pharmaceutical product. The designing of the HVAC should be sorted out while design concept of facility is in progress as it is linked to the architectural layouts like air locks, doorways and lobbies. Once the HVAC system is properly designed and installed it not only helps to create the required room pressure differential cascades but also prevents the cross contamination. Basically an HVAC system works by transferring the heat and moisture into and out of the air and controls the level of the air pollutant either by removing them or diluting them to a particular level. TECHNOLOGY OVERVIEW: HVAC system varies according to the size and installation capacity within a facility but the basic components remain almost the same. LAYOUT OF A TYPICAL BASIC HVAC SYSTEM HEATING SYSTEM: The heat source is either a furnace or ...