Skip to main content

Root Cause Analysis (RCA) in Pharma: WHO & USFDA Guidelines and Proven Methods

 Introduction

In the pharmaceutical industry, when a deviation occurs, we cannot simply "fix and forget." Regulatory bodies like the USFDA and WHO demand that we find out why the failure happened at its deepest level. This process is called Root Cause Analysis (RCA).

If your RCA is weak, your CAPA (Corrective and Preventive Action) will fail, leading to recurring deviations and potential FDA 483 warning letters. In this post, we explore the purpose, regulatory references, and top methods for effective RCA.

Purpose of Root Cause Analysis

The primary goal of RCA is to identify the underlying cause of a problem rather than just treating the visible symptoms.

Prevent Recurrence: Ensuring the same error doesn't happen twice.

Process Improvement: Identifying systemic weaknesses in manufacturing or quality.

Regulatory Compliance: Meeting the expectations of international health authorities.

Patient Safety: Ensuring every batch of medicine meets the required purity and potency.

Regulatory References: What do WHO and USFDA say?

1. WHO GMP (Technical Report Series)

WHO emphasizes that RCA should be a structured part of the Quality Risk Management (QRM) process. According to WHO TRS 981 (Annex 2), RCA must be multidisciplinary. It’s not just a QA job; it involves production, engineering, and lab experts.

2. USFDA (21 CFR Part 211)

The USFDA requires a thorough investigation of any unexplained discrepancy or failure of a batch to meet specifications (21 CFR 211.192). The FDA expects a "written record of the investigation," which must include a clear root cause and follow-up actions.

3. ICH Q9 & Q10

ICH Q9 (Quality Risk Management): Lists RCA as a tool to support risk identification.

ICH Q10 (Pharmaceutical Quality System): Defines RCA as a critical driver for "Continual Improvement of Process Performance and Product Quality."

Top 3 RCA Methods Used in Pharma

To conduct a professional RCA, you shouldn't guess. Use these proven technical tools:

1. The "5 Whys" Technique

This is the simplest tool. You ask "Why?" repeatedly (usually 5 times) until the root cause is revealed.

Example: The tablet hardness is low. Why? The compression force was low. Why? The machine setting was incorrect. Why? The operator followed an old SOP. Why? The new SOP wasn't distributed. (Root Cause: Training/Document Control issue).

2. Fishbone Diagram (Ishikawa / Cause-and-Effect)

This helps you brainstorm by categorizing potential causes into the 6Ms:

Man: Was it human error or lack of training?

Machine: Was there an equipment breakdown?

Method: Was the SOP or process flow flawed?

Material: Was the raw material contaminated?

Measurement: Was the weighing scale out of calibration?

Mother Nature (Environment): Was the humidity too high in the granulation area?

3. FMEA (Failure Mode and Effects Analysis)

A more advanced, data-driven approach that assigns a Risk Priority Number (RPN) to potential failures based on Severity, Occurrence, and Detectability.

Common Pitfall: "Human Error"

One of the biggest mistakes in Pharma RCA is concluding that "Human Error" is the root cause. Auditors hate this. Usually, human error is a symptom of a deeper issue, such as poor lighting, a confusing SOP, or excessive fatigue. Always dig deeper!

Conclusion

Effective Root Cause Analysis is the difference between a "compliance culture" and a "troubled facility." By using structured methods like the Fishbone or 5 Whys and aligning with WHO/FDA guidelines, you ensure your facility stays audit-ready and your patients stay safe.

Popular posts from this blog

Disintegration Time for tablets as per IP, BP and USP

Disintegration Time:- Uncoated Tablet NMT 15 min, in water with Disc 37 0 C ± 2 0 C Coated Tablet NMT 30 min, In water with Disc for Film Coated Tab , and NMT 60 min Other than Film coated tablet Enteric Coated Tab Intact for 2 hr in 0.1 N HCl & disintegrate within 1 hr in Mixed 6.8 Phosphate buffer. According to USP 2 hr in Simulated gastric fluid, then in Simulated Intestinal Fluid. Dispersible/Soluble Within 3 min in water at 25 0 C ± 1 0 C ( IP ) & 15 – 25 0 C ( BP ) Orodispersible Within 1 min Effervescent Tab 5 min in 250 ml water at 20 – 30 0 C ( IP ) & 5  min in 200 ml water at 15-25 0 C ( BP ) Buccal & Sublingual Not Applicable but dissolve within 15 – 30 min. DT Apparatus:- Mesh Apperture:- 2mm (#10), Cycles:- 28 – 32 cycles/min, 50 – 60 mm distance from bottom & top, Temp of water 37 0 C ± 2 0 C. If 1 or 2 tabs fail, repeat for 12 tabs. Click to Buy Here

Weight variation limit for tablet and capsule.

Weight Variation Limits:- 1) For Tablets  IP/BP.                           Limit.                          USP 80 mg or less.             10%                     130mg or less  80 mg to 250mg.       7.5%               130mg to 324mg 250mg or more.          5%               More than 324mg 2) For Capsule:- IP Limit Less than 300mg 10% 300mg or More 7.5%

Basics and use of HVAC system in pharma

HVAC is an essential aspect in pharmaceutical industry as factors like temperature, relative humidity and ventilation have a direct impact on the quality of the pharmaceutical product. The designing of the HVAC should be sorted out while design concept of facility is in progress as it is linked to the architectural layouts like air locks, doorways and lobbies. Once the HVAC system is properly designed and installed it not only helps to create the required room pressure differential cascades but also prevents the cross contamination. Basically an HVAC system works by transferring the heat and moisture into and out of the air and controls the level of the air pollutant either by removing them or diluting them to a particular level. TECHNOLOGY OVERVIEW: HVAC system varies according to the size and installation capacity within a facility but the basic components remain almost the same. LAYOUT OF A TYPICAL BASIC HVAC SYSTEM HEATING SYSTEM: The heat source is either a furnace or ...